• ARD2 Smart Motor Protector

    ARD2 Smart Motor Protector

    ● Suitable for motors with rated voltage of AC380V/660V;

    ● Optional leakage protection, RS485 communication, analog output, etc.

    ● 2 channels DI passive dry node input, signal power supply with built-in DC24V power supply;

    ● 4 channels DO output.

  • ARD2F Smart Motor Protector

    ARD2F Smart Motor Protector

    ● U, I, P, S, PF, F, EP, Leakage, PTC/NTC
    ● 16 protect function
    ● Start control function
    ● 9 programmable DI
    ● 5 programmable DO
    ● Modbus-RTU or Profibus-DP communication
    ● 1 DC4-20mA analog output
    ● 20 fault record
    ● Anti-shaking function

  • WHD20R Din Rail Temperature & Humidity Controller

    WHD20R Din Rail Temperature & Humidity Controller

    ● Temperature and humidity measuring & controlling
    ● LED display
    ● Accuracy: Temperature ±1℃  Humidity ±5%RH
    ● Power supply: AC 85-265V, DC 100-350V

  • WHD72 Panel Mounted Temperature & Humidity Controller

    WHD72 Panel Mounted Temperature & Humidity Controller

    ● Temperature and humidity measuring & controlling
    ● LED display
    ● Accuracy: Temperature ±1℃  Humidity ±5%RH
    ● Power supply: AC 85-265V, DC 100-350V

  • DC Energy Meter PZ72(L)-DE

    DC Energy Meter PZ72(L)-DE

    ●Measure voltage, current, power, forward and reverse power in DC system
    ●Local display
    ●RS485(MODBUS-RTU)
    ●Set parameters
    ●DI/DO, Relay alarm output
    ●Applications:DC panels, solar power, telecommunications base stations, and charging posts
  • WHD46 Panel Mounted Temperature & Humidity Controller

    WHD46 Panel Mounted Temperature & Humidity Controller

    ● Temperature and humidity measuring & controlling
    ● LED display
    ● Accuracy: Temperature ±1℃  Humidity ±5%RH
    ● Power supply: AC 85-265V, DC 100-350V

  • AKH-0.66/K series split core current transformer

    AKH-0.66/K series split core current transformer

    ● Split core current transformer

    ● Easy to install without power off

    ● Suitable for electricity renovation project

  • AMC16Z-ZA Data Center Monitor Device

    AMC16Z-ZA Data Center Monitor Device

    ● Designed specifically for the power supply management of server in the data center

    ● A+B independent 2 channels three-phase inlet

    ● U, I, P, Q, S, PF, kWh, kvarh

    ● 2nd-63rd Harmonic

  • ASJ10-LD1A Residual Current Relay

    ASJ10-LD1A Residual Current Relay

    ● The measurement of A-type after-current;
    ● The streamer display of current percentage;
    ● The setting of rated residual action current;
    ● The setting of non-driving time of limitation;
    ● Two-pair relay output;
    ● Possessing the function of on-the-spot and long-distance testing and resetting.

  • ASJ20-LD1A Residual Current Relay

    ASJ20-LD1A Residual Current Relay

    ● The measurement of A-type residual current;
    ● The streamer display of current percentage;
    ● The setting of rated residual action current;
    ● The setting of non-driving time of limitation;
    ● Two-pair relay output;
    ● Possessing the function of on-the-spot and long-distance testing and resetting.

  • AGF-Mseries Multi channel din rail smart solar string monitor device for pv combiner box

    AGF-Mseries Multi channel din rail smart solar string monitor device for pv combiner box

    *4,8,12,16,20 or 24 string measurement with inner hall effect clamps

    *pv string current input:DC 0-±20A (built-in hall sensor) 

    *Input voltage:DC0-1000V

    *Accuracy:0.5

    *DI(3 external states input,Optocoupler or dry contact)

    *Analog input:PT100,DC0-20ma,DC4-20ma or DC0-10V

    *Communication:Modbus over RS485

    *Auxiliary power supply:DC1000V or DC1500V

  • 24 Channel Temperature Controller ARTM-24

    24 Channel Temperature Controller ARTM-24

    ● 24 PT100,NTC or PT1000measurement;
    ● 2 Alarm relays;
    ● DIN Rail 35mm
    ● Auxiliary power supply adapts with AC220V, DC220V, DC110V;
    ● 1 RS485 serial communication, Modbus-RTU;

  • AM2SE Series Medium Current Protection Relays

    AM2SE Series Medium Current Protection Relays

    AM2SE Protection Relays used for 10 kv voltage applications.

    Used for the protection of Line,Feeder

    Cut out: 150*68mm

     

  • AM3SE Series Medium Voltage Protection Relays

    AM3SE Series Medium Voltage Protection Relays

    ● A complete set of protection, related to the application;
    ● 5 current input, 3 voltage input, 11DI, 5DO;
    ● Auxiliary power supply adapts with AC 220V, DC 220V, DC 110V, AC 110V, DC 48V, DC 24V;
    ● 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU;
    ● 1 GPS for GPS timing;

     

  • BA Series Split Current Transducer

    BA Series Split Current Transducer

    ●Model: BA20(II)-AI,BA50(II)AI
    ●Aperture: 20mm,50mm
    ●Input: AC0-600A
    ● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
    ●Overload: 1.2 times of rated value
    ●Power supply: DC12V/DC24V

  • AIM-T500 Insulation Monitoring Device for undergrounded system up to AC690V or DC800V

    AIM-T500 Insulation Monitoring Device for undergrounded system up to AC690V or DC800V

    ● AC, DC main circuits 
    ● AC/DC main circuits with directly connected DC components, such as rectifiers
    ● Systems with switch-mode power supplies
    ● Systems with high leakage capacitances
  • ADW300-WF WiFi Energy Meter for IOT Platform Electricity Consumption Monitoring

    ADW300-WF WiFi Energy Meter for IOT Platform Electricity Consumption Monitoring

    ● Measures active kWh (positive and negative), quadrant reactive energy, U, I, P, Q, S, PF, F, etc.
    ● Communication: RS485, Infrared communication, Lora, WiFi, 4G, NB-IOT
    ● THDv, Harmonic on 2nd-31st
    ● Max demand
    ● Accuracy:Class 0.5S
    ● 4DI/2DO
    ● Measures temperature of A/B/C/N
    ● Measures 1 channel of leakage current
    ● Power outage alarm
    ● HMI Programming: Setting of CT/PT Ratio, Phase Wiring, Communication and etc
    ● Standard&Certificate: CE; IEC

  • AKH-0.66/TD-50III Series of Current Transformers

    AKH-0.66/TD-50III Series of Current Transformers

    ● Measurement: Alternating Current (AC)
    ● Rated Voltage: 660V AC
    ● Accuracy: Class 0.2
     Primary Current Input: 300~800A AC
     Primary Current Input: 20mA, 5A
    ● Rated Frequency: 50~60Hz
    ● Installtion: installed on busbar
     Loop Count: 1 Loop
     Sandard&Certificate: GB 156-2017; UL
    ● Ambient temperature: -30℃ ~90℃

  • AKH-0.66/TD-60 Series of Current Transformers

    AKH-0.66/TD-60 Series of Current Transformers

    ● Measurement: Alternating Current (AC)
    ● Rated Voltage: 660V AC
    ● Accuracy: Class 0.2
     Primary Current Input: 300~1000A AC
     Primary Current Input: 20mA, 50mA
    ● Rated Frequency: 50~60Hz
    ● Installtion: installed on wires
     Loop Count: 1 Loop
     Sandard&Certificate: GB 156-2017; UL
    ● Ambient temperature: -30℃ ~90℃

  • ADL400/C 3 Phase Energy Meter for IOT Platform Electricity Consumption Monitoring

    ADL400/C 3 Phase Energy Meter for IOT Platform Electricity Consumption Monitoring

    ● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
    ● Communication: RS485(Modbus-RTU)
    ● Harmonic on 2nd-31st
    ● Multi tariff
    ● Max demand and and occurrence time
    ● Frozen data on last 48 months, last 90 days
    ● Accuracy:Class 0.5
    ● Active pulse output
    ● 12 bits section LCD display, background light
    ● 3 keys to communication and set parameters
    ● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×220/380V
    ● Rated current: 3×1(6)A, 3×10(80)A
    ● Standard&Certificate: MID; CE; IEC