ADL200 Single Phase Din Rail Energy Meter
● AC220V
● 10(60), 10(80), 20(100)A
● RS485(MODBUS-RTU)
● Set parameters
● LCD display
● kWh Class 1
● DIN 35 mm -
ADW220 Multi Channel Wireless Energy Meter
● Mearsure Up to 4 circuit 3 phase
● Lora (470/433MHz) wireless communication
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs),MTL(temperature measurement and leakage current measurement), AWT100(wireless communication)
-
DTSD1352 Three Phase Din Rail Energy Meter
● AC 3×220/380V,3×380V,3×57.7/100V,3×100V
● 3×1(6)A,3×10(80)A, 3×20(100)A
● U、I、P、Q、S、PF、kWh、kvarh
● RS485(MODBUS-RTU)
● LCD display
● Frozen data
● 2-31st Harmonics
● kWh Class 0.5S,kVarh Class 2 -
ADL3000-E/CT Three Phase Din Rail Energy Meter with 3 split CTs
● AC 3×220/380V,3×380V,3×57.7/100V,3×100V
● 3×1(6)A, 3×20(100)A
● U、I、P、Q、S、PF、kWh、kvarh
● RS485(MODBUS-RTU)
● LCD display
● Frozen data
● 2-31st Harmonics
● kWh Class 0.5S,kVarh Class 2 -
ADW210 Series Multi-Loop Power Meter
● Mearsure Up to 4 circuit 3 phase
● LCD display
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs),MTL(temperature measurement and leakage current measurement), AWT100(wireless communication)
-
ADW200 Series Multi Channel Energy Meter
● Mearsure Up to 4 circuit 3 phase
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs),MTL(temperature measurement and leakage current measurement), AWT100(wireless communication) -
ADW210 Multi Channel Wireless Energy Meter
● Mearsure Up to 4 circuit 3 phase
● Lora (470/433MHz) wireless communication
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs),MTL(temperature measurement and leakage current measurement), AWT100(wireless communication)
-
ADL3000-E/C(DTSD1352-C) 3 Phase Energy Meter for IOT Platform Electricity Consumption Monitoring
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
● Communication: 2 channels of RS485(Modbus-RTU), Infrared communication
● Harmonic on 2nd-31st
● Multi tariff
● Max demand and and occurrence time
● Frozen data on last 48 months, last 90 days
● Support 3 outlay NTC temperature
● 1 DI/1 DO
● Accuracy:Class 0.5
● Active pulse output, reactive pulse output, clock pulse output
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×220/380V
● Rated current: 3×1(6)A, 3×10(80)A
● Standard&Certificate: CE; IEC -
ADL200/C Single Phase Energy Meter for IOT Platform Electricity Consumption Monitoring
● Measurement: Active kWh (positive and negative), reactive power, U, I, P, Q, S, PF, F, etc.
● Communication: RS485(Modbus-RTU), Infrared communication
● Multi tariff
● Data Record: 3 months historical energy data frozen storage(optional)
● Accuracy:Class 1.0
● Pulse output: Active energy pulse output
● Display: 8 digits display U, I, P, Q, PF, kWh and other energy consumption
● 3 keys to set parameters, such as code, address, baud rate, multi-tariff and communication protocol
● Rated voltage: AC 220V, 230V
● Rated current: 10(80)A, measure 0.01A-80A
● Standard&Certificate: MID, CE, IEC -
DJSF1352-RN DC Energy Meter for Solar Power
● Measurement: kWh, U, I, P, Q, S, etc.
● Measures 2 channels of DC energy(optional)
● Measures bidirectional DC energy
● Communication: RS485(Modbus-RTU),2 channels of RS485(optional)
● Communication protocol: Modbus-RTU, DL/T 645-2007
● Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V)
● Voltage input range: DC0-1000V
● Input signal: Shunt:0-75mV;Hall sensor:0-20mA, 4-20mA, 0-5V, 0-10V and so on.
● 2DI/2DO
● Power supply: AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)
● Accuracy: 1 or 0.5 (connected via shunt)(optional)
● Switch output: 2 Relay outputs, 2A/30VDC or 2A/250VAC
● Switch input: 2 dry contact inputs
● Pulse output: A second pulse output, an energy pulse output
● Display: 8 digits display U, I, P, Q, kWh and other energy consumption
● Average barrier-free working hours: ≥50000h
● Mounted: Din rail 35mm
● Standard & Certificate: CE; IEC -
ADW210 Multi-channel 3 Phase Energy Meter
● Measures 4 channels of 3 phase circuits
● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc.
● Communication: RS485(Modbus-RTU)
● Harmonic on 2nd-31st
● Multi tariff: 4 time zones 14Periods rate setting;
● Maximum Current, maximum power demand and real time Current, real time power demand;
● Record of voltage, current and power extreme of current month and last month;
● 200 event records, record the action of DIDO;
● Support over-voltage, over-current, phase failure, DI linkage and other alarm output;
● Accuracy: Class 0.5
● 12 channel Switching inputs+4 channel Switching outputs;
● 12 bits section LCD display, background light
● 12 channel external NTC temperature +4 channel residual current measurement (leakage current);
● Rated voltage: 3×220/380V
● Rated current: 5A( secondary transforming), 100A, 400A, 600A. -
ADW200 Multi-channel 3 Phase Energy Meter
● Measures 4 channels of 3 phase circuits
● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc.
● Communication: RS485(Modbus-RTU)
● Harmonic on 2nd-31st
● Multi tariff: 4 time zones 14Periods rate setting;
● Maximum Current, maximum power demand and real time Current, real time power demand;
● Record of voltage, current and power extreme of current month and last month;
● 200 event records, record the action of DIDO;
● Support over-voltage, over-current, phase failure, DI linkage and other alarm output;
● Accuracy: Class 0.5
● 12 channel Switching inputs+4 channel Switching outputs;
● 12 bits section LCD display, background light
● 12 channel external NTC temperature +4 channel residual current measurement (leakage current);
● Rated voltage: 3×220/380V
● Rated current: 5A( secondary transforming), 100A, 400A, 600A. -
ADW220 Multi-channel 3 Phase Energy Meter
● Measures 4 channels of 3 phase circuits
● Measures 3 phase power, total power (active, reactive, apparent), U, I, P, Q, S, PF, F, zero sequence current, voltage/current phase angle, voltage/current degree of unbalance, etc.
● Communication: RS485(Modbus-RTU), Lora
● Harmonic on 2nd-31st
● Multi tariff: 4 time zones 14Periods rate setting;
● Maximum Current, maximum power demand and real time Current, real time power demand;
● Record of voltage, current and power extreme of current month and last month;
● 200 event records, record the action of DIDO;
● Support over-voltage, over-current, phase failure, DI linkage and other alarm output;
● Accuracy: Class 0.5
● 12 channel Switching inputs+4 channel Switching outputs;
● 12 bits section LCD display, background light
● 12 channel external NTC temperature +4 channel residual current measurement (leakage current);
● Rated voltage: 3×220/380V
● Rated current: 5A( secondary transforming), 100A, 400A, 600A. -
ADW300 series Wireless Energy Meter for IOT Platform
● Communication: 4G,WiFi,LoRa,LoRaWAN, RS485
● Measurement: 3 Phase voltage, current, power, power factor, etc
● Application: Building, Factory, Smart Grids, DB Room and etc
● Rated Voltage: AC 3*220/380V,3*230/400V
● Rated Current: AC 3×1(6)A
● Standard&Certificate: CE,IEC,LVD
-
ADW300-WF WiFi Energy Meter for IOT Platform Electricity Consumption Monitoring
● Measures active kWh (positive and negative), quadrant reactive energy, U, I, P, Q, S, PF, F, etc.
● Communication: RS485, Infrared communication, Lora, WiFi, 4G, NB-IOT
● THDv, Harmonic on 2nd-31st
● Max demand
● Accuracy:Class 0.5S
● 4DI/2DO
● Measures temperature of A/B/C/N
● Measures 1 channel of leakage current
● Power outage alarm
● HMI Programming: Setting of CT/PT Ratio, Phase Wiring, Communication and etc
● Standard&Certificate: CE; IEC -
ADL3000-E/CTC(DTSD1352-CTC) 3 Phase Energy Meter
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
● Communication: 2 channels of RS485(Modbus-RTU), Infrared communication
● Harmonic on 2nd-31st
● Multi tariff
● Max demand and and occurrence time
● Frozen data on last 48 months, last 90 days
● Support 3 outlay NTC temperature
● 1 DI/1 DO
● Accuracy:Class 0.5S
● Active pulse output, reactive pulse output, clock pulse output
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×220/380V
● Rated current: 3×1(6)A, 3×10(100)A
● Standard&Certificate: CE; IEC -
ACR10-DXXTE4 3 Phase Energy Power Meter with CTs for Solar Inverter
● Type: ACR10-DXXTE4
● Rated voltage: AC 100V or 400V
● Rated current:AC 80A,120A,200A
● RS485(MODBUS-RTU)
● Certificate: CE -
ADL300-EY Three Phase Prepaid Energy Meter
● AC 3×220/380V
● 1(6)A,10(80)A
● Prepaid mode
● Alarm for dump energy
● LCD display
● Historical records
● kWh Class 0.5S
● DIN 35 mm -
DDSY1352 Single Phase Prepaid Energy Meter
● AC 220V
● 10(60)A
● Prepaid mode
● LCD display
● Historical records
● kWh Class 1
● DIN 35 mm -
AEW100 Wireless Energy Meter
● RS485 and Infrared communication
● Lora communication on 470MHz
● Rated I: 1.5(6)A,20(100)A,40(200)A,80(400)A,120(600)A
● Rated U: 3×220/380V,3*380V,3*57.7/100V
● kWh Class 1
● DIN 35 mm