● Model:ATC600-C
● Measuring 240 points(ATE100M/ATE200/ATE400/ATE200P/ACE100/AHE100);
● Power supply:DC12~48V/ AC/DC 85~265V
● Wireless distance, Receiver sensor 150m (in open area),Relay distance 1Km (in open area);
● 1 RS485 serial communication, Modbus-RTU
● 2 alarm relays
● Installation:DIN35mm
● Wireless temperature measurement, maximum 60 points;
● 4 digital inputs;
● 2 alarm relays;
● LCD display;
● Auxiliary power supply AC220V, DC220V, DC110V, AC110V;
● 1 RS485 serial communication, Modbus-RTU.
● Temperature and humidity measuring & controlling ● LED display ● Accuracy: Temperature ±1℃ Humidity ±5%RH ● Power supply: AC 85-265V, DC 100-350V
● 8 or 24 PT100 measurement;
● 2 Alarm relays;
● LED display;
● Auxiliary power supply adapts with AC220V, DC220V, DC110V;
● 1 RS485 serial communication, Modbus-RTU;
● Model: ATE100
● Wireless transmit,470MHz;
● Wireless transmission distance, 150 meters;
● Fast sampling frequency, 25s;
● Battery -powered, more than 5 years;
● Widely temperature measuring range, -50℃~+125℃.
● Model: ATE200
● Model: ATE400
● Fast sampling frequency, 15s;
● CT powered,starting current ≥5A
● Model: ATE100M
AM4 Protection Relays used for 10 kv voltage applications.
Used for the protection of Line,Feeder, Transformer, PT supervision
widely used in construction, industry, energy and other fields.
AM5 Protection Relays used for 10 kv voltage application
Application: Line/Feeder, Motor, Bus tie,Capacitor,Transformer,PT etc
Panel size:267*164mm Cut out: 245.5*158mm
● Suitable for motors with rated voltage of AC380V/660V;
● Optional leakage protection, RS485 communication, analog output, etc.
● 2 channels DI passive dry node input, signal power supply with built-in DC24V power supply;
● 4 channels DO output.
● U, I, P, S, PF, F, EP, Leakage, PTC/NTC ● 16 protect function ● Start control function ● 9 programmable DI ● 5 programmable DO ● Modbus-RTU or Profibus-DP communication ● 1 DC4-20mA analog output ● 20 fault record ● Anti-shaking function
● The measurement of A-type after-current; ● The streamer display of current percentage; ● The setting of rated residual action current; ● The setting of non-driving time of limitation; ● Two-pair relay output; ● Possessing the function of on-the-spot and long-distance testing and resetting.
● The measurement of A-type residual current; ● The streamer display of current percentage; ● The setting of rated residual action current; ● The setting of non-driving time of limitation; ● Two-pair relay output; ● Possessing the function of on-the-spot and long-distance testing and resetting.
● 24 PT100,NTC or PT1000measurement; ● 2 Alarm relays; ● DIN Rail 35mm ● Auxiliary power supply adapts with AC220V, DC220V, DC110V; ● 1 RS485 serial communication, Modbus-RTU;
AM2SE Protection Relays used for 10 kv voltage applications.
Used for the protection of Line,Feeder
Cut out: 150*68mm
● A complete set of protection, related to the application; ● 5 current input, 3 voltage input, 11DI, 5DO; ● Auxiliary power supply adapts with AC 220V, DC 220V, DC 110V, AC 110V, DC 48V, DC 24V; ● 1 RS485 serial communication, IEC60870-5-103 and Modbus-RTU; ● 1 GPS for GPS timing;