ADL200 Single Phase Din Rail Energy Meter
● AC220V
● 10(60), 10(80), 20(100)A
● RS485(MODBUS-RTU)
● Set parameters
● LCD display
● kWh Class 1
● DIN 35 mm -
ADW220 Multi Channel Wireless Energy Meter
● Mearsure Up to 4 circuit 3 phase
● Lora (470/433MHz) wireless communication
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs),MTL(temperature measurement and leakage current measurement), AWT100(wireless communication)
-
DC Energy Meter PZ72(L)-DE
● Measure voltage, current, power, forward and reverse power in DC system● Local display● RS485(MODBUS-RTU)● Set parameters● DI/DO, Relay alarm output● Applications:DC panels, solar power, telecommunications base stations, and charging posts -
AMC**L-AI Single Phase Current Meter
● Type: AMC48L-AI,AMC72L-AI,AMC96L-AI
● AC current: AC1A or 5A
● 1 x RS485 with programmable Modbus RTU;
● Optional function: Alarm, Analog output, DI/DO and communication;
● Economic programmable meter;
● Accuracy: Class 0.5 -
ADF400L Multi-circuits Energy Meter
● Measure largest 36 circuits single-phase
or 12 circuits three-phase
● AC 3 * 220 / 380V
● 3×1(6)A,3×10(80)A
● RS485(MODBUS-RTU)
● Set parameters
● LCD display
● kWh Class 0.5
● DIN 35 mm -
APM Series of Multifunction Energy Meter
● True RMS Measurements
● THD with 63rd Harmonics
● K-Factor and Crest Factor
● Unbalance & Phase Angles
● Demands and Multi-Tariff energy
● Max/Min Log with Timestamp -
AMC96L-E4/KC Programmable Energy Meter
● Type: AMC96L-E4/KC
● Size: 96*96mm
● True RMS Measurements
● THD with 2-31st Harmonics
● Max/Min Log with Timestamp
● Internal Optional 4DI&2DO or 2DI&2DO&2AO
● Standard one Energy Pulse Output -
DTSD1352 Three Phase Din Rail Energy Meter
● AC 3×220/380V,3×380V,3×57.7/100V,3×100V
● 3×1(6)A,3×10(80)A, 3×20(100)A
● U、I、P、Q、S、PF、kWh、kvarh
● RS485(MODBUS-RTU)
● LCD display
● Frozen data
● 2-31st Harmonics
● kWh Class 0.5S,kVarh Class 2 -
AMC**L-AV3 Three Phase Voltage Meter
● Type: AMC48L-AV3,AMC72L-AV3,AMC96L-AV3
● AC current: AC100V,220V,380V
● 1 x RS485 with programmable Modbus RTU;
● Optional function: Alarm, Analog output, DI/DO and communication;
● Economic programmable meter;
● Accuracy: Class 0.5 -
ADF400 Series Multi-circuits Energy Meter
● Measure largest 36 circuits single-phase
or 12 circuits three-phase
● AC 3 * 220 / 380V
● 3×1(6)A,3×10(80)A
● RS485(MODBUS-RTU)
● Set parameters
● LCD display
● kWh Class 0.5
● DIN 35 mm -
AMC96L-E4/KC 3 Phase Panel Energy Meter
● Type: AMC96L-E4/KC
● Size: 96*96mm
● True RMS Measurements
● THD with 2-31st Harmonics
● Max/Min Log with Timestamp
● Internal Optional 4DI&2DO or 2DI&2DO&2AO
● Standard one Energy Pulse Output -
ADL3000-E/CT Three Phase Din Rail Energy Meter with 3 split CTs
● AC 3×220/380V,3×380V,3×57.7/100V,3×100V
● 3×1(6)A, 3×20(100)A
● U、I、P、Q、S、PF、kWh、kvarh
● RS485(MODBUS-RTU)
● LCD display
● Frozen data
● 2-31st Harmonics
● kWh Class 0.5S,kVarh Class 2 -
AMC72(L)-DV DC Voltage Meter
● Measure voltage in DC system● Local display● RS485(MODBUS-RTU)● Set parameters● DI/DO, Relay alarm output● Applications:DC panels, solar power, telecommunications base stations, and charging posts -
AMC72(L)-DI DC Current Meter
● Current in: 75mV(via shunt) 0-20mA,4-20mA(via hall sensor)
● Power supply:AC/DC85-265V
● Accuracy:class0.5
-
ADW210 Series Multi-Loop Power Meter
● Mearsure Up to 4 circuit 3 phase
● LCD display
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs),MTL(temperature measurement and leakage current measurement), AWT100(wireless communication)
-
ADW200 Series Multi Channel Energy Meter
● Mearsure Up to 4 circuit 3 phase
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs),MTL(temperature measurement and leakage current measurement), AWT100(wireless communication) -
ADW210 Multi Channel Wireless Energy Meter
● Mearsure Up to 4 circuit 3 phase
● Lora (470/433MHz) wireless communication
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs),MTL(temperature measurement and leakage current measurement), AWT100(wireless communication)
-
ADL3000-E/C(DTSD1352-C) 3 Phase Energy Meter for IOT Platform Electricity Consumption Monitoring
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
● Communication: 2 channels of RS485(Modbus-RTU), Infrared communication
● Harmonic on 2nd-31st
● Multi tariff
● Max demand and and occurrence time
● Frozen data on last 48 months, last 90 days
● Support 3 outlay NTC temperature
● 1 DI/1 DO
● Accuracy:Class 0.5
● Active pulse output, reactive pulse output, clock pulse output
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×220/380V
● Rated current: 3×1(6)A, 3×10(80)A
● Standard&Certificate: CE; IEC -
ADL200/C Single Phase Energy Meter for IOT Platform Electricity Consumption Monitoring
● Measurement: Active kWh (positive and negative), reactive power, U, I, P, Q, S, PF, F, etc.
● Communication: RS485(Modbus-RTU), Infrared communication
● Multi tariff
● Data Record: 3 months historical energy data frozen storage(optional)
● Accuracy:Class 1.0
● Pulse output: Active energy pulse output
● Display: 8 digits display U, I, P, Q, PF, kWh and other energy consumption
● 3 keys to set parameters, such as code, address, baud rate, multi-tariff and communication protocol
● Rated voltage: AC 220V, 230V
● Rated current: 10(80)A, measure 0.01A-80A
● Standard&Certificate: MID, CE, IEC -
DJSF1352-RN DC Energy Meter for Solar Power
● Measurement: kWh, U, I, P, Q, S, etc.
● Measures 2 channels of DC energy(optional)
● Measures bidirectional DC energy
● Communication: RS485(Modbus-RTU),2 channels of RS485(optional)
● Communication protocol: Modbus-RTU, DL/T 645-2007
● Built-in Bipolar Power Source: Power Supply for Hall Effect CT (DC -12V ~ DC +12V)
● Voltage input range: DC0-1000V
● Input signal: Shunt:0-75mV;Hall sensor:0-20mA, 4-20mA, 0-5V, 0-10V and so on.
● 2DI/2DO
● Power supply: AC/DC 85-265V or DC24V(±10%) or DC48V(±10%)
● Accuracy: 1 or 0.5 (connected via shunt)(optional)
● Switch output: 2 Relay outputs, 2A/30VDC or 2A/250VAC
● Switch input: 2 dry contact inputs
● Pulse output: A second pulse output, an energy pulse output
● Display: 8 digits display U, I, P, Q, kWh and other energy consumption
● Average barrier-free working hours: ≥50000h
● Mounted: Din rail 35mm
● Standard & Certificate: CE; IEC