• AHBC-LTA Closed-loop Hall current sensor

    AHBC-LTA Closed-loop Hall current sensor

    General Closed-loop Hall current sensor is also...
  • AKH-0.66I Series Current Transformer

    AKH-0.66I Series Current Transformer

    They are patented and flip designed. The appearance is nice and the wiring is convenient. The transparent polycarbonate material is selected for the flip.We can clearly see the secondary lead wiring. It have square-round hole for both cable and bus passing through . As alternating current signal acquisition element,it is generally matched with measuring instruments and widely used in electrical sets.

  • Split Core Current Transformer

    Split Core Current Transformer

    Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They are connected with the panel meter or relay and they can help to measure the current or protect the equipment.

  • Open Hall Current Sensor

    Open Hall Current Sensor

    Rated current input:0-(50-5000)A

    Rated output: 5v / 4v / 4-20mA

    Aperture: 20mm/40mm/55mm/etc

    Power supply: ±15V / 12V / 24V

  • AKH-0.66/K-24 Series Current Transformer

    AKH-0.66/K-24 Series Current Transformer

    Current Transformer (CT) is used to transform the high AC current to small easily manageable values. They are connected with the panel meter or relay and they can help to measure the current or protect the equipment.

  • AKH-0.66/K-36 Series Current Transformer

    AKH-0.66/K-36 Series Current Transformer

    Current Transformer (CT) is used to transform the high AC(300-600A) current to small easily manageable values. They are connected with the panel meter or relay and they can help to measure the current or protect the equipment.

  • Split Core Current Transformer

    Split Core Current Transformer

    ● Split core current transformer

    ● Accuracy: class 0.5

    ● Suitable for electricity renovation project

  • AC Current Transducer Measuring 0-200A

    AC Current Transducer Measuring 0-200A

    ●Model: BA20-AI/I, BA20-AI/V
    ●Aperture: 20mm
    ●Input: AC0-(8-50)A
    ● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
    ●Overload: 1.2 times of rated value
    ●Power supply: DC12V/DC24V

  • AC Current Transducer Measuring 0-50A

    AC Current Transducer Measuring 0-50A

    ●Model: BA10-AI/I, BA10-AI/V
    ●Aperture: 9.5mm
    ●Input: AC0-(8-50)A
    ● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
    ●Overload: 1.2 times of rated value
    ●Power supply: DC12V/DC24V

  • AC Straight Through Current Transducer

    AC Straight Through Current Transducer

    ●Model: BA05,BA10,BA20,BA50
    ●Aperture: 5mm,10mm,20mm,50mm
    ●Input: AC0-10A,AC0-50A,AC0-200A,AC0600A
    ● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
    ●Overload: 1.2 times of rated value
    ●Power supply: DC12V/DC24V

  • AC Current Transducer Measuring 0-600A

    AC Current Transducer Measuring 0-600A

    ●Model: BA50-AI/I, BA50-AI/V
    ●Aperture: 50mm
    ●Input: AC0-(60-600)A
    ● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
    ●Overload: 1.2 times of rated value
    ●Power supply: DC12V/DC24V

  • AC Leakage Current Transducer

    AC Leakage Current Transducer

    ● Model: BA50L-AI/I, BA50L-AI/V
    ● Input: AC0-1A
    ● Analog Output: DC 0-5V/1-5V/0-20mA/4-20mA
    ● Overload: 1.2 times of rated value
    ● Power supply: DC12V/DC24V

  • AKH-0.66/Z Series integrated Current Transformer

    AKH-0.66/Z Series integrated Current Transformer

    1. Combined current transformer is also called the three-phase current transformer.
    2. As current signal acquisition device, it is generally matched with multi-loop current monitoring device (AMC16), PZ300, moulded case circuit breaker and other products.
    3. It can save installation space, reduc the cumbersome wiring, be convenient to use and effectively reduce the cost.

  • AKH-0.66/K series split core current transformer

    AKH-0.66/K series split core current transformer

    ● Split core current transformer

    ● Easy to install without power off

    ● Suitable for electricity renovation project

  • AKH-0.66/I series current transformer

    AKH-0.66/I series current transformer

    ● Current transformer for measurement

    ● Suitable for cables or copper bus

    ● Used with energy meters or relays

    Standards

    IEC/EN61869-1, IEC/EN61869-2
  • AKH-0.66/TD-50III Series of Current Transformers

    AKH-0.66/TD-50III Series of Current Transformers

    ● Measurement: Alternating Current (AC)
    ● Rated Voltage: 660V AC
    ● Accuracy: Class 0.2
     Primary Current Input: 300~800A AC
     Primary Current Input: 20mA, 5A
    ● Rated Frequency: 50~60Hz
    ● Installtion: installed on busbar
     Loop Count: 1 Loop
     Sandard&Certificate: GB 156-2017; UL
    ● Ambient temperature: -30℃ ~90℃

  • AKH-0.66/TD-60 Series of Current Transformers

    AKH-0.66/TD-60 Series of Current Transformers

    ● Measurement: Alternating Current (AC)
    ● Rated Voltage: 660V AC
    ● Accuracy: Class 0.2
     Primary Current Input: 300~1000A AC
     Primary Current Input: 20mA, 50mA
    ● Rated Frequency: 50~60Hz
    ● Installtion: installed on wires
     Loop Count: 1 Loop
     Sandard&Certificate: GB 156-2017; UL
    ● Ambient temperature: -30℃ ~90℃