-
ACR10R-D16TE4 Three Phase Energy Meter for Solar Inverters
● 3 Phase 4 Wires, 3 Phase 3 Wires
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), Apparent kWh (positive and negative),U, I, P, Q, S, PF, F, etc.
● Accuracy: Class 0.5
● Communication: RS485(Modbus-RTU)
● Rated voltage: 3*57.5VV/100V, 3*220V/380V(400V)
● Rated current: 80A, 120A, 200A, 300A
● Power supply: AC85-265V, or DC100-350V; DC24V(±10%); DC48V(±10%)
● Standard & Certificate: CE, etc.
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters -
ACR10R-D16TE Single Phase Energy Meter for Solar Inverters
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), Apparent kWh (positive and negative),U, I, P, Q, S, PF, F, etc.
● Accuracy: Class 0.5
● Rated current: 80A, 120A, 200A, 300A
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 220V(±20%)
● Rated current: 80A, 120A, 200A, 300A
● Power supply: AC85-265V, or DC100-350V; DC24V(±10%); DC48V(±10%)
● Standard & Certificate: CE, etc. -
ADL3000-E/C(DTSD1352-C) 3 Phase Energy Meter for IOT Platform Electricity Consumption Monitoring
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
● Communication: 2 channels of RS485(Modbus-RTU), Infrared communication
● Harmonic on 2nd-31st
● Multi tariff
● Max demand and and occurrence time
● Frozen data on last 48 months, last 90 days
● Support 3 outlay NTC temperature
● 1 DI/1 DO
● Accuracy:Class 0.5
● Active pulse output, reactive pulse output, clock pulse output
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×220/380V
● Rated current: 3×1(6)A, 3×10(80)A
● Standard&Certificate: CE; IEC -
Inverter Monitoring Energy Meter
●Type: AGF-AE/D200●Single phase three wire●Rated voltage: AC 120V/208V,240V(88%~110%)●Rated current: AC 100A , 200A●Application: inverters in Australia, Europe, North America and other areas●DIN 35 mm -
DC Voltage Meter AMC72(L)-DV
●Measure voltage in DC system●Local display●RS485(MODBUS-RTU)●Set parameters●DI/DO, Relay alarm output●Applications:DC panels, solar power, telecommunications base stations, and charging posts -
Single Phase Energy Meter With External Split CTs
●Type:ACR10R-D10TE,ACR10R-D16TE,ACR10R-D24TE,ACR10R-D36TE
●Current input:80A,120A,200A,300A
●Measurement current、voltage、active power, reactive power, power factor
●RS485 communication interface
●The interfaces with switch input and relay output
●LCD display -
APM Series of Multifunction Energy Meter
● True RMS Measurements
● THD with 63rd Harmonics
● K-Factor and Crest Factor
● Unbalance & Phase Angles
● Demands and Multi-Tariff energy
● Max/Min Log with Timestamp -
3 Phase Energy Power Meter with CTs for Solar Inverter
● Type: ACR10-DXXTE4
● Rated voltage: AC 100V or 400V
● Rated current:AC 80A,120A,200A
● RS485(MODBUS-RTU)
● Certificate: CE -
Single Phase Energy Meter With External Split CTs for PV System
●Type:ACR10R-D10TE,ACR10R-D16TE,ACR10R-D24TE,ACR10R-D36TE
●Current input:80A,120A,200A,300A
●Measurement current、voltage、active power, reactive power, power factor
●RS485 communication interface -
ADW350WD Multi-Circuits DC Energy Meter
● Voltage input: DC48V Current input:100a/5v(include 3 hall sensor)● Measurement: 3 channel voltage,current,power,etc.● Communication:RS485,4G,NB● Accuracy:Class 1.0 -
DC Energy Meter PZ72(L)-DE
●Measure voltage, current, power, forward and reverse power in DC system●Local display●RS485(MODBUS-RTU)●Set parameters●DI/DO, Relay alarm output●Applications:DC panels, solar power, telecommunications base stations, and charging posts -
ADL3000-E/CTC(DTSD1352-CTC) 3 Phase Energy Meter
● Measures active kWh (positive and negative), Reactive kWh (positive and negative), U, I, P, Q, S, PF, F, etc.
● Communication: 2 channels of RS485(Modbus-RTU), Infrared communication
● Harmonic on 2nd-31st
● Multi tariff
● Max demand and and occurrence time
● Frozen data on last 48 months, last 90 days
● Support 3 outlay NTC temperature
● 1 DI/1 DO
● Accuracy:Class 0.5S
● Active pulse output, reactive pulse output, clock pulse output
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 3×100V, 3×380V, 3×57.7/100V, 3×220/380V
● Rated current: 3×1(6)A, 3×10(100)A
● Standard&Certificate: CE; IEC -
Three Phase Din Rail Energy Meter with 3 split CTs
● AC 3×220/380V,3×380V,3×57.7/100V,3×100V
● 3×1(6)A, 3×20(100)A
● U、I、P、Q、S、PF、kWh、kvarh
● RS485(MODBUS-RTU)
● LCD display
● Frozen data
● 2-31st Harmonics
● kWh Class 0.5S,kVarh Class 2